1-620 Trouble locating and clearing procedures (continued)
TOPS MPX Token Ring LAN troubleshooting
09/21/91 13:06:56 DFIPD214E Unable to close ring adapter
––––––>
Message
Number
DFIPD215E
DFIPD216I
297-8021-544 Standard 14.02 May 2001
0011
Return Code
Adapter Number
Explanation
Message:
Ring adapter or lobe failed
Meaning: The Ring Diagnostic determines if a wire fault is
present. When this message displays, ring status is Wire Fault.
Action: Record the ring status. Replace the defective cable
and run the Ring Diagnostic again to verify the problem is
corrected.
Variable Data: Does not apply.
Message:
Ring adapter Closed
Meaning: This message can occur because the user presses
F3 (End). The message can also occur when an error forces
the adapter to close. When this message displays, ring status
is Adapter Closed.
Action: If the reason code is 00, there is no action required. If
the reason code is 01 or 03, run the Adapter Diagnostics. If the
diagnostics determine the adapter is defective, replace the
position in according to standard practices.
Variable Data:
(continued)