Nortel North American DMS-100 Instruction Manual page 671

Table of Contents

Advertisement

1-650 Trouble locating and clearing procedures (continued)
VSLE session defaults to audio SLE
18
19
20
21
22
23
24
297-8021-544 Standard 14.02 May 2001
and press Enter.
where
unit_no
is the number of the PM (0 or 1)
Note: CMR is an optional parameter that means to return only the CMR
card to service.
The following card list is a standard message that refers to a CMR card
failure.
RTS Failed, TESTALL
Diagnostic TESTALL failed.
Fail message received from PM
Replace the Cards in the Card List
and applicable Paddleboards (i.e. 6X12) :
Site Flr RPos Bay_id
HOST
01
D02 LGE
If RTS
passes
fails but the CMR card is not on
the card list
fails and the CMR card is on the
card list
Perform PM maintenance on the PM currently posted. Go to step 23.
Go to step 23.
Use the following information to determine the next step in this procedure.
If
a first-time replacement of the
CMR card
replaced CMR card already
Monitor the active side of the PM and run diagnostics on the inactive side.
Go to step 23.
For additional help, contact the person responsible for the next level of
support.
The procedure is complete.
(end)
Shf
Description
00
18
LGC : 000
Do
step 23
step 18
step 19
Do
step 12
step 22
Slot
EqPEC
13
6X78