Nortel North American DMS-100 Instruction Manual page 388

Table of Contents

Advertisement

7
8
9
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Trouble locating and clearing procedures (continued)
Scheduling an automatic REx test
and press Enter.
where
h1 m1
is the start time of the REx test on the 24 h clock, for example, 02 30
h2 m2
is the end time of the REx test on the 24 h clock, for example, 04 30
Note: The value in NODEREXCONTROL must allow enough time to test
all the LIMs that you want to test. Add 30 minutes to the parameter of all
LIMs.
Example input:
>Y 02
30
04
30
Example of a MAP response:
TUPLE TO BE CHANGED:
NODEREXCONTROL
ENTER Y TO CONFIRM, N TO REJECT, OR E TO EDIT.
To confirm the change, type
>Y
and press Enter.
Example of a MAP response:
TUPLE CHANGED
To quit from the table editor and return to the CI level of the MAP display, type
>QUIT
and press Enter.
CAUTION
Possible loss of service
Do not isolate nodes on the F-bus of the LIM you are testing.
If you isolate any of the nodes on the F-bus of the LIM you
are testing, the REx test will not proceed.
To post the LIM that you want to include in the REx test, type
>MAPCI;MTC;PM;POST
and press Enter.
where
lim_no
is the number of the first LIM that you will post (0 to 16)
Y 02 30 04 30
LIM
lim_no
1-373
(continued)