Replacing an 8-in. or a 5.25-in. disk drive unit
Card 8
5
6
7
8
9
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Trouble locating and clearing procedures (continued)
where
card_no
is the number of the controller card (0 to 8)
Note: In the example in step 3, the number of the controller card is 8.
Example of a MAP display:
Unit
0
User
SYSTEM
Status
BSY
Record the number of the replaced DDU.
Note: In the example in step 4, the number of the DDU is 0.
Determine the state of the disk drive.
Note: The Drive_State header displays the state of the disk drive on the
MAP display.
If the disk drive
is being allocated
is other than listed here
To determine if any files are open on the DDU, type
>ALLOC
and press Enter.
Example of a MAP response:
VOLID VOL_NAME SERIAL_NO BLOCKS ADDR TYPE R/O
FILES_OPEN 0
IMAGE
XPMLOADs
2801
20000 D000 0 NO
0 NO
0 8 AMA1
2809
50 D000
0 NO
NO
0
If open files
are present
are not present
Record the name and size (in blocks) of each disk volume.
To test the disk drive, type
>TST
and press Enter.
Example of a MAP response:
Drive_State
spinning
Do
step 68
step 9
2800
45000 D000
35000 D000 0 NO
0
.
.
. 7 SMDR
2808
5000 D000 0 NO
0 10
AMA2
Do
step 67
step 8
(continued)
0 NO
0 1
0 2 RTMLOADS
2802
2807
5000 D000
0 9 TST
280A
500 D000
1-97
0