1-340 Trouble locating and clearing procedures (continued)
Running a C7BERT
95
96
97
98
99
297-8021-544 Standard 14.02 May 2001
(continued)
If
the link stops on an NT9X77AA or
NT9X78BA/CA/DA/DB card, and you just ran a link
fault sectionalization. If instructions required you to
perform more tests
link does not stop on an NT9X77AA or
NT9X78BA/CA/DA/DB card
other than listed here
Remove the manual loopback across network elements.
The next step depends on the instructions received from the next level of
support.
If
instructions require you to return
the link to service
instructions require you to per-
form more tests
other than listed here
To remove the link fault sectionalization, type
>LFSLOOP
STOP
link_no
and press Enter.
where
link_no
is the number of the tested link (0 to 15)
If the response
is LFSLoop stop n
is Link n: LFS OFF complete
is other than listed here
To quit the C7BERT level of the MAP display, type
>QUIT
and press Enter.
To activate the link that the C7BERT ran on, type
>ACT
link_no
and press Enter.
Do
step 70
step 95
step 110
Do
step 98
step 73
step 110
Do
step 98
step 109

Advertisement