Nortel North American DMS-100 Instruction Manual page 343

Table of Contents

Advertisement

1-328 Trouble locating and clearing procedures (continued)
Running a C7BERT
53
54
55
56
297-8021-544 Standard 14.02 May 2001
(continued)
where
link_no
is the number of the link (0 to 15) that the C7BERT runs on
day
is the day you want the test to stop automatically (MON, TUE, WED,
THU, FRI, SAT, or SUN)
hours
is the hour you want the test to stop automatically (0 to 23)
minutes
is the minute you want the test to stop automatically (00 to 59)
Example input:
>SETSTOP
3
SET
Note: The example entry sets the stop time for link 3 on every Monday at
10:30 a.m.
If the response
is Link nn: Stop time set at:
is 19xx/yy/zz
is hh:mm:00.000 ddd
is other than listed here
Determine if the stop time is correct.
If the stop time
is correct
is wrong
Wait until the C7BERT stops.
Go to step 45.
To quit the C7BERT level of the MAP display, type
>QUIT
and press Enter.
To activate the link that the C7BERT ran on, type
>ACT
link_no
and press Enter.
where
MON
10
30
Do
step 53
step 66
Do
step 54
step 51

Advertisement