1-510 Trouble locating and clearing procedures (continued)
TOPS MP Operator complaint (standalone)
Clearing voice communication path trouble
11
12
13
At the TAMI
14
Example of a TAMI response
15
297-8021-544 Standard 14.02 May 2001
Replace the conference circuit card. Refer to Card Replacement Procedures
and return to this step.
To test the posted CF3P circuit again, type:
>TST
and press the Enter key.
If test
passes
fails
Perform the common procedure Removing an MP position from service
(standalone) .
To access the Diagnostics screen from the TAMI main menu, type:
>5
and press the Enter key.
Enter TPC Diagnostics command:
To run the position component diagnostics (TCD) test, type:
>POSDIAG n TCD
and press the Enter key.
where
n
is the MP position number (0,1, 2, or 3)
(continued)
Do
step 17
step 13