Nortel North American DMS-100 Instruction Manual page 269

Table of Contents

Advertisement

1-254 Trouble locating and clearing procedures (continued)
Replacing a point-of-use power supply card
16
17
18
19
20
297-8021-544 Standard 14.02 May 2001
Clamp the insertion and withdrawal tool to the front edge of the replacement
card, as shown in step 11. Align the card with the socket and carefully insert
the card.
Make sure the card sits in a secure position.
Carefully push the drawer back into the shelf until the thumb-latch button
locks.
To return the drawer to service, type
>RTS
DRWR
drawer_no
and press the Enter key.
where
drawer_no
is the logical number of the line drawer, 00 to 15
The procedure is complete. Return to the main procedure that sent you to
this procedure and continue to follow the directions.
(end)