1-108 Trouble locating and clearing procedures (continued)
Replacing an 8-in. or a 5.25-in. disk drive unit
55
56
57
58
59
WARNING:
Writing label of Volume IMAGE
Successful
Starting Initialization of Volume IMAGE
A break HX of this process may cause severe corruption
on this volume that may require reinitialization of all
non initialized volumes.
Number of Bad Blocks = 0
Successful
Update Done
60
297-8021-544 Standard 14.02 May 2001
where
ddu_no
is the DDU number (0 to 9) recorded in step 5
To confirm the command, type
>YES
and press Enter.
To add a volume to the disk, type
>ADD
vol_name
vol_size
and press Enter.
where
vol_name
is the volume name recorded in step 8
vol_size
is the volume size recorded in step 8
To add the volume to the root directory, type
>DIRADD
vol_name
and press Enter.
where
vol_name
is the volume name recorded in step 8
Repeat steps 55 and 57 for each of the remaining disk volumes.
To enforce the allocation of the volumes, type
>UPDATE
and press Enter.
Example of a MAP response:
A break HX of this process may cause
severe corruption on the disk that may
require it to be reformatted.
To quit the allocation utility, type
>QUIT
and press Enter.
(continued)