Nortel North American DMS-100 Instruction Manual page 414

Table of Contents

Advertisement

Softkey information does not download to the ADSI set
12
13
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Trouble locating and clearing procedures (continued)
unit_no
is the number of the PM unit (0 or 1)
Note: CMR is an optional parameter that means to busy only the CMR
card
To load the CMR card, type
>LOADPM UNIT unit_no CC CMR
and press Enter.
where
unit_no
is the number of the PM unit (0 or 1)
Note: CMR is an optional parameter that means to load only the CMR
card.
Follow the directions in the table.
If
the loading completes correctly
CMR FAILED TO LOAD.
WHILE LOADING CMR
CMR FILE CMRXXX NOT FOUND ON DEVICE
INDICATED IN TABLE PMLOADS
Note:CMRXXX is the CMR load name.
FAILED TO OPEN CORRECTLY
Verify that the CMR card can load. To use the QUERYPM CNTRS command
to determine the CMR load name, type
>QUERYPM CNTRS
and press Enter.
Example of a MAP response:
TASK ABORTED
1-399
(continued)
Do
step 13
step13
step 13
step 13

Advertisement

Table of Contents
loading

Table of Contents