TOPS MPX Token Ring LAN troubleshooting
(Sheet 4 of 4)
Message
Number
DFIPD018I
DFIPD019E
DFIPD040E
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Trouble locating and clearing procedures (continued)
Explanation
Message:
Ring test 2 successful - test complete
Meaning: Ring test 2 is complete. The Adapter Support
Interface and adapter sent out a message that returned
correctly. This message appears after the message number
DFIPD016I.
Action: There is no action required.
Variable Data: Does not apply
Message:
Ring test 2 failed - test is complete
Meaning: Ring test 2 did not send a message around the ring.
The Adapter Support Interface or this adapter does not send or
receive the message correctly.
This message appears when message DFIPD230E displays
and the Ring Diagnostic starts.
Action: When ring status is Normal, run the Adapter
Diagnostics. Make sure the diagnostics indicate that the
adapter functions and the message repeats. Remove and
replace the TOPS MPX position. Follow the common
procedures. Install the replacement TOPS MPX. Begin the
test. Use the TOPS MPX power-on self test. If the known
working TOPS MPX position flags this error, a problem with the
adapter cable or the MAU is present.
Variable Data: Does not apply
Message:
Ring Diagnostic initialization failed.
Meaning: The Ring diagnostic cannot start correctly. The error
is caused by an internal program error or by the creation of the
back-up copy of the System Disk.
Action: Refer to the variable data and to the chart below to
determine the reason for failure.
Variable Data:
1-597