1-224 Trouble locating and clearing procedures (continued)
Replacing a missing line card
Replacing a missing line card
At the MAP terminal
1
2
3
4
5
6
297-8021-544 Standard 14.02 May 2001
(continued)
To access the LTP level of the MAP display, type
>MAPCI;MTC;LNS;LTP
and press the Enter key.
To post the line equipment number (LEN) of the line that has faults, type
>POST
L
len
and press the Enter key.
where
len
is the LEN of the damaged line. Use the format ff u dd cc for frame,
unit, drawer, and circuit number.
Example input:
>POST
L
00
1
Example of a MAP response
LCC PTY RNG ...LEN....
1FR
HOST 00 1 00 01 613 621 4777 IDL
To locate the missing line card, type
>CKTLOC
and press the Enter key.
Example of a MAP response
Site Flr RPos
Bay_id
HOST
00 B00
LCE 00
GRD START
2DB LOSS
NO
NO
Record the product engineering code (PEC), the PEC suffix, and the location
of the line card that has faults.
Note: The PEC appears In the MAP response in step 3. The PEC
appears under the EqPEC header. The location appears under the Site,
Flr, RPos, Bay_id, Sh, Description, and Slot headers.
To replace the line card that you recorded in step 4, perform the correct
procedure in Card Replacement Procedures . Complete the procedure and
return to this point.
To perform a diagnostic test on the line card that you installed in step 5, type
>DIAG
and press the Enter key.
Example of a MAP response
00
01
DN
STA F S LTA TE RESULT
Sh
Description Slot
38
LCM 00 1
BAL NETWORK
MAN
NON LOADED
EqPEC
00:01 6X17AC
OVR
SET
NO