1-386 Trouble locating and clearing procedures (continued)
Setting up the signaling link marginal performance report
Setting up the signaling link marginal performance report
At the MAP terminal
1
2
3
4
5
6
7
8
297-8021-544 Standard 14.02 May 2001
To access the CM level of the MAP display, type
>MAPCI;MTC;CM
and press Enter.
Determine if the computing modules (CM) have a synchronized status.
To quit from the CM level of the MAP, type
>QUIT ALL
and press Enter.
To access table OFCVAR, type
>TABLE
OFCVAR
and press Enter.
To position on the office parameter C7_SLMPR_ALARM_ON, type
>POSITION
C7_SLMPR_ALARM_ON
and press Enter.
Example of a MAP response:
C7_SLMPR_ALARM_ON
Determine the value of the office parameter.
If the value
is Y
is N
To change the value of the field to Y, type
>CHANGE
2
Y
and press Enter.
Example of a MAP response:
TUPLE TO BE CHANGED:
C7_SLMPR_ALARM_ON
ENTER Y TO CONFIRM, N TO REJECT or E TO EDIT.
To confirm the command, type
>Y
and press Enter.
Example of a MAP response:
TUPLE CHANGED
N
Do
step 9
step 7
Y
(continued)