Nortel North American DMS-100 Instruction Manual page 353

Table of Contents

Advertisement

1-338 Trouble locating and clearing procedures (continued)
Running a C7BERT
87
88
89
90
91
297-8021-544 Standard 14.02 May 2001
(continued)
Determine the result of bit error injection.
Note: In the example in step 87, the number of bit errors received appears
to the right of Rx Bit Errors.
Subtract the result of the C7BERT recorded in step 84 from the result
obtained in step 87.
If the difference
is 6
is other than listed here
To determine if any requests existed for periodic reports, type
>REPORT
link_no
and press Enter.
where
link_no
is the number of the link (0 to 15) that the C7BERT runs on
If the response
is Link nn: Report interval al-
ready set at: mm times per hour
is Link nn: Automatic query re-
porting is not active
is other than listed here
To clear the last report interval, type
>REPORT
link_no
and press Enter.
where
link_no
is the number of the link that the C7BERT runs on
MAP response:
Link nn: Automatic query reporting has been terminated
To set the number of reports per hour, type
>REPORT
link_no
and press Enter.
where
link_no
is the number of the link (0 to 15) that the C7BERT runs on
Do
step 82
step 109
STATUS
Do
step 90
step 91
step 109
OFF
ON
number