Clearing voice communication path trouble
10
11
12
13
At the MAP
14
Example of a MAP response
Performing ROM position Component Diagnostic...
Performing CPU position Component Diagnostic...
Performing Exceptions position Component Diagnostic...
Performing RAM position Component Diagnostic...
Performing HSLI Port position Component Diagnostic...
Performing UART position Component Diagnostic...
Performing Keyboard position Component Diagnostic...
Performing Telephony position Component Diagnostic...
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Trouble locating and clearing procedures (continued)
TOPS MP Operator complaint (integrated)
and press the Enter key.
If test
passes
fails
To locate the circuit card that has faults, type:
>CKTLOC
and press the Enter key.
Replace the conference circuit card. Refer to Card Replacement Procedures
and return to this point.
To test the posted CF3P circuit again, type:
>TST
and press the Enter key.
If test
passes
fails
Perform the common procedure Removing the MP position from service
(integrated) .
To run the position component diagnostics (TCD) test, type:
>TST TERM
and press the Enter key.
If test
passes
Do
step 13
step 10
Do
step 16
step 13
Do
step 16