TOPS MP Operator complaint (standalone/integrated)
6
reset
switch
7
8
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Trouble locating and clearing procedures (continued)
Clearing ORDB access trouble
CAUTION
Service interruption
Use of the reset switch takes all MP positions associated with
the TPC out of service. Make sure you return to service all
MP positions associated with this TPC at the end of the
procedure.
To set the TPC again, move the switch on the SBC card in slot 6 to the down
position. Return the switch to the up position.
6
Remove the Diagnostic Boot diskette and insert the Diagnostic Run diskette.
Leave the Diagnostic Run diskette in the disk drive until the system requests
you to remove it.
To run the diagnostic test on the HSDA card type:
>HSDADIAG n
press the Enter key.
where
n
is the card number
TPC packfill SBC card
1-527
(continued)