DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Trouble locating and clearing procedures (continued)
Bay_id
in ISDN-line concentrating equipment, bay 01
Shf
on shelf 18
Description
in hardware device LCME, bay 01
Slot
in slot 02, drawer 09
Note: In this example, the PEC of the line card is BX27AA.
Record the location and PEC for the line card.
WARNING
Static electricity damage
When you handle circuit cards, wear a wrist-strap that
connects to the wrist strap grounding point of a frame
supervisory panel (FSP). The wrist-strap protects the cards
against static electricity damage.
Locate the drawer for the line card. Use the information you recorded in step
2.
Press the small thumb-latch button on the lower left edge of the drawer.
Carefully pull the drawer toward you until it stops.
Replacing a line card