TOPS MPX Token Ring LAN troubleshooting
09/21/91 13:06:56 DFIPD081I Ring poll failure
––––––>
Message
Number
DFIPD109I
09/21/91 13:06:56 DFIPD109I Ring monitor error – ring recovered
––––––>
Message
Number
DFIPD110I
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Trouble locating and clearing procedures (continued)
10005A0002B2 10005A000352
Reporting
Address of
Adapter
Last Adapter
Address
Responding to
Ring Poll
Explanation
Message:
Ring monitor error - ring recovered
Meaning: The ring recovers after a ring monitor error occurs.
This message appears only when Full E.R. is activated. When
this message appears, ring status is Normal or Soft Error.
Action: There is no action required.
Variable Data:
1005A0002B2 0002 00000000 10005A000352
Ring
Error
Monitor
Reason
Address
Code
Explanation
Message:
Error reporter failed - processing continues
Meaning: The system logs the message when the Ring
Diagnostic detects an adapter that is not congested any longer.
Action: There is no action required.
Variable Data: Does not apply
Ring
NAUN
Monitor
Adapter
Physical
Address
Address
1-607