1-496 Trouble locating and clearing procedures (continued)
TOPS MP Operator complaint (standalone)
Clearing position failure - cannot RTS position
Example of a TAMI response
38
39
40
41
42
At the TAMI
43
297-8021-544 Standard 14.02 May 2001
Performing ROM position Component Diagnostic...
Performing CPU position Component Diagnostic...
Performing Exceptions position Component Diagnostic...
Performing RAM position Component Diagnostic...
Performing HSLI Port position Component Diagnostic...
Performing UART position Component Diagnostic...
Performing Keyboard position Component Diagnostic...
Performing Telephony position Component Diagnostic...
If TCD diagnostics test
passes
fails
fails with base controller re-
placed
To exit the Diagnostics screen, type:
>QUIT
and press the Enter key.
Replace the base controller. Go to Card Replacement Procedures and return
step 37.
Replace the new base controller with the original base controller replaced in
step 39. Go to Card Replacement Procedures and return to the next step.
To exit the Diagnostics screen, type:
>QUIT
and press the Enter key.
Perform the common procedure Placing MP positions in service
(standalone) .
Examine the Position Status/Control menu.
If the VDU displays
InSv
SysB
(continued)
Do
step 41
step 38
step 40
Do
step 45
step 44