Nortel North American DMS-100 Instruction Manual page 387

Table of Contents

Advertisement

1-372 Trouble locating and clearing procedures (continued)
Scheduling an automatic REx test
Scheduling an automatic REx test
At the MAP terminal
1
2
3
4
5
6
297-8021-544 Standard 14.02 May 2001
To access table OFCVAR, type
>TABLE
OFCVAR
and press Enter.
To position on office parameter NODEREXCONTROL, type
>POSITION
NODEREXCONTROL
and press Enter.
Example of a MAP response:
NODEREXCONTROL Y 1 30 3 30
Note: In the example, Y indicates the activation of the REx test. 1 30 is the
start time of the REx test on the 24-h clock. 3 30 is the end time of the REx
test on the 24-h clock.
To display the fields and tuples, type
>LIST
and press Enter.
Example of a MAP response:
PARMNAME
NODEREXCONTROL
To specify that you want to change office parameter NODEREXCONTROL,
type
>CHANGE
and press Enter.
MAP response:
ENTER Y TO
CONTINUE PROCESSING
OR N TO QUIT
To continue to process, type
>Y
and press Enter.
Example of a MAP response:
PARMVAL: Y 1 30
To activate automatic REx testing, and enter a new value for office parameter
NODEREXCONTROL, type
>Y
h1
m1
h2
m2
(continued)
3 30
PARMVAL
Y 1 30