Nortel North American DMS-100 Instruction Manual page 106

Table of Contents

Advertisement

At the MAP terminal
20
21
22
23
24
25
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Trouble locating and clearing procedures (continued)
To manually busy the DDU, type
>BSY
and press Enter.
Example of a MAP display:
bsy
OK
If the BSY command
passed
failed
To start the DDU, type
>START
and press Enter.
Example of a MAP response:
Disk start successful
To test the DDU, type
>TST
and press Enter.
Example of a MAP display:
Process may take up to 3 minutes.
Test OK
If the TST command
passed
failed
To perform volume allocation tests, follow the procedure Allocating test
volumes on 8-in., 5.25-in., or 3.5 in. DDUs in Routine Maintenance
Procedures . When the procedure is complete, return to this point.
To perform interference and file transfer tests, follow the procedure
Performing DDU interference and file transfer tests in Routine Maintenance
Procedures . When the procedure is complete, return to this point.
To access the CI level of the MAP display, type
>QUIT ALL
and press Enter.
Replacing a 3.5 in. disk drive unit
NTFX32BA
Do
step 21
step 38
Do
step 23
step 38
1-91
(continued)