Nortel North American DMS-100 Instruction Manual page 266

Table of Contents

Advertisement

Replacing a point-of-use power supply card
4
5
6
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Trouble locating and clearing procedures (continued)
and press the Enter key.
To post the LCME that contains the line card, type
>POST
LCME
HOST
and press the Enter key.
where
frame_no
is the frame number of the LCEI
module_no
is the module number of the LCME, 00 or 01
Example of a MAP display:
LCME HOST 67 1 SysB Links OOS: Cside 0
Unit0: SysB
Unit1: SysB
Drwr: 01 23 45 67 89 01 23 45
.. ..
..
..
CAUTION
Loss of service
When the drawer busies, there will be a loss of subscriber
service on all lines in the drawer.
To manually busy the drawer, type
>BSY
DRWR
drawer_no
and press the Enter key.
where
drawer_no
is the logical number for the line drawer, 00 to 15
Example of a MAP display:
WARNING this action will affect both drawers 0 and 1
LCME HOST 07 1 Drwr 0 will be out of service
Confirm ("YES", "Y", "NO", or "N"):
To confirm the command, type
>YES
and press the Enter key.
frame_no
module_no
11 11 11 RG: Uneq
..
..
..
..
1-251
(continued)

Advertisement

Table of Contents
loading

Table of Contents