1-250 Trouble locating and clearing procedures (continued)
Replacing a point-of-use power supply card
Replacing a point-of-use power supply card
At the MAP terminal
1
2
3
297-8021-544 Standard 14.02 May 2001
WARNING
Possible equipment damage
Proceed only when a step in a maintenance procedure directs
you to this procedure. Separate use of this procedure can
cause equipment damage or loss of service.
To display the location and product engineering code (PEC) for the line card
for the PUPS card, type
>MAPCI;MTC;LNS;LTP;LTPISDN
>Post D or L <Dir No.> or <Len No.>
>CKTLOC
and press the Enter key.
Example of a MAP response:
CKTLOC
Site Flr RPos Bay_id Shf Description Slot EqPEC
HOST 03 C04 LCEI36 18 LCME 00 01 02:09 BX27AA
Note: In this example, the location of the line card is
Site
in the HOST office
Flr
on the 3rd floor
RPos
in row C, position 04
Bay_id
in ISDN LCME, bay 36 (identifies the type of equipment in the bay)
Shf
on shelf 18
Description
in LCME module 00, unit 01
Slot
in slot 02, logical drawer 09
Note: In this example, the PEC of the line card is BX27AA.
Record the location of the line card.
Note: The PUPS card is in the same drawer as the line card.
To access the PM level of the MAP display, type
>PM
(continued)