1-356 Trouble locating and clearing procedures (continued)
Running a C7BERT for high-speed links
query 1 pr
Link
Run Time
Tx Frames
Rx Frames
Rx Bit Errors:
Bit Err Rate : 0 x 10–15
41
42
297-8021-544 Standard 14.02 May 2001
link_no
is the number of the link being tested (0 to 15)
Example of a MAP response:
1: C7BERT query
:
662
:
19016
:
19019
If the response is
a display of HSL C7BERT sta-
tistics
anything else
Determine if any Tx frames were transmitted.
Note: The number of frames transmitted appears to the right of the Tx
Frames header of the MAP display. In the example in step 40, the number
of frames transmitted is 19 016.
If
any Tx frames were transmitted
no Tx frames were transmitted
The test is running correctly.
Test results generate when:
the periodic reporting function is active
operating company personnel stop the test manually
the test stops automatically at a pre-set time
Note: If the switch restarts when an HSL C7BERT is running on a link, the
test stops automatically. The test also stops automatically if the HLIU
associated with the link fails.
If
you want to request periodic re-
ports
you want to stop the test manual-
ly
(continued)
Err Free Secs:
Rx Sync Errs :
Rx Bad Frames:
0
Rx Bits
Do
step 41
step 78
Do
step 42
step 78
Do
step 54
step 58
662
0
0
:
38931896