1-322 Trouble locating and clearing procedures (continued)
Running a C7BERT
32
33
34
297-8021-544 Standard 14.02 May 2001
(continued)
Determine the if any transmitted Tx frames exist.
Note: The number of frames transmitted appears to the right of the Tx
Frames header of the MAP display. In the example in step 31, the number
of frames transmitted is 19 016 .
If Transmitted Tx Frames
are present
are not present
The test runs correctly. The C7BERT generates test results when you request
periodic reports, stop the test manually, or stop the test automatically at a
preset time. Decide the action you want to take.
Note: If a switch restart occurs when a C7BERT runs on a link, the test
stops automatically. If the LIU7 for the link fails, the test also stops
automatically.
If
you want to request periodic re-
ports
you want to stop the test manual-
ly
you want to stop the test auto-
matically at a preset time
the
link
connects
NT9X78DA/DB card and you
want to inject bit errors
To display C7BERT results, type
>QUERY
link_no
and press Enter.
where
link_no
is the number of the tested link. (0 to 15)
Example of a MAP response:
Do
step 33
step 66
Do
step 40
step 44
step 50
to
a
step 34