1-334 Trouble locating and clearing procedures (continued)
Running a C7BERT
76
77
78
297-8021-544 Standard 14.02 May 2001
(continued)
link_no
is the number of the link that the C7BERT runs on
If the response
is Stop time cleared
is other than listed here
To set the stop time that is new, type
>SETSTOP
link_no
and press Enter.
where
link_no
is the number of the link (0 to 15) that the C7BERT runs on
day
is the day you want the test to stop automatically (MON, TUE, WED,
THU, FRI, SAT, or SUN)
hours
is the hour you want the test to stop automatically (0 to 23)
minutes
is the minute you want the test to stop automatically (00 to 59)
Example input:
>SETSTOP
3
SET
Note: The example entry sets the stop time for link 3 on every Monday at
10:30 a.m.
If the response
is Link nn: Stop time set at:
is 19xx/yy/zz
is hh:mm:00.000 ddd
is other than listed here
Determine if the stop time is correct.
If the stop time
is correct
is wrong
Wait until the C7BERT stops.
Go to step 94.
Do
step 76
step 109
SET
day
hours
MON
10
30
Do
step 77
step 109
Do
step 78
step 75
minutes