1-494 Trouble locating and clearing procedures (continued)
TOPS MP Operator complaint (standalone)
Clearing position failure - cannot RTS position
Example of a TAMI response
28
Example of a TAMI response
29
30
31
32
297-8021-544 Standard 14.02 May 2001
and press the Enter key.
Enter TPC Diagnostics command:
To test the HSLI card, type:
>POSDIAG n CARD
and press the Enter key.
where:
n
is the card position on the TPC (0, 1, 2, or 3)
Performing CBT Port Register Test...
Performing CC Port Register Test...
Performing CBT Port Internal Loopback Test...
Performing CC Port Internal Loopback Test...
Performing HSLI Port Register Test...
Performing HSLI Port Ram Test...
If card diagnostics test
passes
fails
fails with HSLI card replaced
Note: You can select ManB positions only.
To exit the Diagnostics screen, type:
>QUIT
and press the Enter key.
Replace the HSLI card. Go to Card Replacement Procedures and return to
step 28.
To exit the Diagnostics screen, type:
>QUIT
and press the Enter key.
Perform the common procedure Placing an MP position in service
(standalone) .
(continued)
Do
step 31
step 29
step 34