Nortel North American DMS-100 Instruction Manual page 199

Table of Contents

Advertisement

1-184 Trouble locating and clearing procedures (continued)
Replacing a digital audio tape (DAT) drive
NTFX32CA
(continued)
Replacing a digital audio tape (DAT) drive
At your current location
1
2
297-8021-544 Standard 14.02 May 2001
Obtain the following items:
replacement tape drive assembly
flat-blade screwdriver with a 1/4 in. (3-mm) blade
Obtain a shipping carton for the DAT drive that you will replace. When
possible, use the carton of the new drive.
To access the IOD level of the MAP display, type
>MAPCI;MTC;IOD
and press Enter.
Example of a MAP display:
IOD
IOC
0
2
3
STAT .
.
S
DIRP: SMDR B XFER:
MLP :
.
DPPP:
To post the input/output module (IOM) controller for the replaced DAT drive,
type
>IOC ioc_no
and press Enter.
where
ioc_no
is the number of the affected IOM
Example of a MAP display:
IOC
PORT 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
(IOM)STAT . . . – . . –
0
TYPE C C C
O O O
N N N
.
SLM:
.
.
DPPU:
.
– – .
C M
M
O T
P
N D
C
NPO:
.
NX25:
SCAI:
– . .
S
C
S
S
C
S

Advertisement