Nortel North American DMS-100 Instruction Manual page 200

Table of Contents

Advertisement

3
Port 16
(SCSI)
4
5
6
7
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Trouble locating and clearing procedures (continued)
Replacing a digital audio tape (DAT) drive
To post the port for the replaced DAT drive, type
>PORT port_no
and press Enter.
where
port_no
is the port number of the DDU device
Example of a MAP display:
MTD 1
TapeName
Status
Record the number of the replaced DAT drive.
Notify all users that there will be an interruption in service for the device. Wait
until all users stop use of the DAT drive before you proceed to the next step.
To demount a mounted DAT tape, type
>DEMOUNT
Tmtd_no
and press Enter.
where
mtd_no
is the number of the affected MTD (DAT)
To manually busy the DAT drive port, type
>BSY
and press Enter.
Example of a MAP display:
bsy
OK
If the BSY command
passed
failed
NTFX32CA
DevType
DAT
User
Idle
Do
step 8
step 19
1-185
(continued)