1-246 Trouble locating and clearing procedures (continued)
Replacing an NTFX39 bulkhead splitter unit
37
38
39
40
41
42
At the MAP terminal
43
44
45
46
47
297-8021-544 Standard 14.02 May 2001
Replace the splitter unit.
Secure the replacement unit with the nuts.
Reconnect the four cable connectors (C05 to C08) at the front of the splitter
unit. Reconnect the shrouded pin unit connections at the back of the unit.
Repeat step 36 for the cable connectors and shrouded pin connections on the
second IOM.
The next action depends on the reason for the performance of this procedure.
If a maintenance procedure
directed you to this procedure
did not direct you to this proce-
dure
Return to the maintenance procedure that sent this procedure and continue
as directed.
To return an IOM to service, type
>RTS IOC
and press Enter.
The next action depends on any provisioned consoles, disk drives and
magnetic tape drives.
If provisioned consoles, disk
drives and magnetic tape drive
ports
are present
are not present
To post the device port, type
>PORT
port_no
and press Enter.
where
port_no
is the port identification number (0 to 17)
To return the device to service, type
>RTS
and press Enter.
Repeat steps 45 and 46 for all provisioned disk drives, consoles, and
magnetic tape drive ports.
(continued)
Do
step 42
step 43
Do
step 45
step 48