1-628 Trouble locating and clearing procedures (continued)
Troubleshooting a customer-reported failure
No FRIU alarms
6
7
8
9
10
11
12
297-8021-544 Standard 14.02 May 2001
(continued)
To access the PM level of the MAP display, type
>MAPCI; MTC; PM
and press Enter.
To post the FRIU identified in step 4, type
>POST
FRIU
friu_no
and press Enter.
where
friu_no
is the FRIU number obtained in step 4
If the FRIU
is SysB
is SysB (NA)
is ManB
is ManB (NA)
is ISTb
is ISTb (NA)
is InSv (NA)
is InSv
Perform the procedure Clearing a PM FRIU critical alarm (on an LPP) in
Alarm and Performance Monitoring Procedures . Do not return to this
procedure.
Perform the procedure Clearing a PM FRIU major alarm (on an LPP) in Alarm
and Performance Monitoring Procedures . Do not return to this procedure.
Perform the procedure Clearing a PM FRIU minor alarm (on an LPP) in Alarm
and Performance Monitoring Procedures . Do not return to this procedure.
Determine from the MAP banner if any alarms are present under the PM
header.
If alarms
are present
are not present
Perform the correct alarm clearing procedures. Refer to Alarm and
Performance Monitoring Procedures .
Do
step 8
step 8
step 9
step 9
step 10
step 8
step 11
step 13
Do
step 12
step 13