1-536 Trouble locating and clearing procedures (continued)
TOPS MP TAMI trouble (standalone)
Clearing TAMI response failure
Clearing TAMI response failure
At your current location
1
2
3
4
297-8021-544 Standard 14.02 May 2001
(continued)
Use the documentation of the manufacturer to determine if the TAMI baud
rate is set at 1200 baud.
If TAMI baud rate is
1200
not 1200
Use the documentation of the manufacturer to set the baud rate to 1200.
Determine if TAMI responds.
If TAMI
responds
does not respond
Check the frame fail light on the frame supervisory panel (FSP) to determine
if the TPC has a power outage.
Do
step 4
step 2
Do
step 9
step 4