DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Trouble locating and clearing procedures (continued)
The failure occurred for one of the following reasons:
•
The element type and occurrence specified is beyond the location of the
link problem.
•
There is no element type and occurrence.
Go to step 109.
To stop the C7BERT that exists, type
>STOP
link_no
and press Enter.
where
link_no
is the number of the link that you entered in step 67
Note: The STOP command overrides the preset stop time without
warning.
If the response
is Link 1: C7BERT stopped
is other than listed here
Apply manual loopbacks to the network elements that you will test.
To determine if a stop time is set, type
>SETSTOP
link_no
and press Enter.
where
link_no
is the number of the link (0 to 15) that the C7BERT runs on
If the response
is Link nn: Stop time set at:
is time
is Link nn: No set stop time.
is other than listed here
To clear the stop time, type
>SETSTOP
link_no
and press Enter.
where
Running a C7BERT
Do
step 67
step 109
STATUS
Do
step 75
step 76
step 109
CLEAR
1-333
(continued)