Nortel North American DMS-100 Instruction Manual page 107

Table of Contents

Advertisement

1-92 Trouble locating and clearing procedures (continued)
Replacing a 3.5 in. disk drive unit
NTFX32BA
(continued)
26
27
28
29
30
WARNING:
Writing label of volume IMAGE
Successful
Starting initialization of volume IMAGE
A break HX of this process may cause severe corruption on
this volume that may require reinitialization of all
non-initialized volumes.
Number of bad blocks=0
Successful
Update done
31
32
297-8021-544 Standard 14.02 May 2001
To access the allocation utility, type
>DSKALLOC ddu_no
and press Enter.
where
ddu_no
is the recorded DDU number in step 4.
To confirm the command, type
>YES
and press Enter.
To add a volume to the DDU, type
>ADD vol_name vol_size; DIRADD vol_name
and press Enter.
where
vol_name
is the recorded volume name in step 7.
vol_size
is the recorded volume size in step 7.
Repeat step 28 for each disk volume that remains.
To enforce the allocation of the volumes, type
>UPDATE
and press Enter.
Example of a MAP response:
A break HX of this process may cause severe
corruption on the disk that may require it to
be reformatted.
To quit the allocation utility, type
>QUIT
and press Enter.
To post the IOM controller port for the DDU, type
>MAPCI;MTC;IOD;IOC ioc_no;PORT port_no

Advertisement

Table of Contents
loading

Table of Contents