DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Trouble locating and clearing procedures (continued)
Troubleshooting a customer-reported failure
Check the operational measurements (OM) that apply to DataSPAN. Look for
high counts of cyclic redundancy test (CRC) errors in:
OM group FRSAGENT, register PTERR for each involved agent
OM group FRSPM, register PORTERR for each involved device
OM group FRT1, register FRT1CRC for the involved carrier
For example, to check register FRT1CRC for OM group FRT1, type
>OMSHOW FRT1 ACTIVE 3
and press Enter.
Example of a MAP response
CLASS:
ACTIVE
START:1997/08/21 21:15:00 THU; STOP:1997/08/21 21:16:10 THU;
SLOWSAMPLES:
INFO (FRT1OMINF)
FRT1LCGA
FRT1RCGA
FRT1MBU
FRT1CBU
FRT1SES
FRT1UAS
3 FRIU
29
0
0
0
For more information on OMs, refer to Operational Measurements Reference
Manual .
To post the access channel, type
>CARR;CHAN;POST
and press Enter.
where
chan_no
is the channel number that appeared in response to the PVDNCI
command
Example of a MAP display
CARRIER
InSv
CHANNEL
1
N
CHANNEL
1
( 24
InSv /NoLMI
To check the traffic level on the access channel, type
>QTRAFFIC
No FRIU alarms
1;
FASTSAMPLES
FRT1LOF
FRT1SBU
FRT1BER
FRT1ES
FRT1AIS
FRT1CRC
0
0
0
0
0
0
0
0
0
chan_no
Alarm
BER
<–9.
x DS0)
(continued)
7;
ES
SES
UAS
0
0
211
1-629