Nortel North American DMS-100 Instruction Manual page 619

Table of Contents

Advertisement

1-598 Trouble locating and clearing procedures (continued)
TOPS MPX Token Ring LAN troubleshooting
09/21/91 13:06:56 DFIPD040E Ring diagnostic initialization failed
––––––> 0010 10005A00133 000000A33832 000000A33832 000000A33832
(Sheet 1 of 2)
Reason
Code
0002
0003
0007
0008
000A
000E
000F
0010
0015
0018
297-8021-544 Standard 14.02 May 2001
Reason
The
Code
Address of
this
Adapter
Reason
Initialize command fails.
Open command fails.
Status command fails.
Adapter already in use.
Parameters were not passed to
the Ring Diagnostic.
Wrong optional parameter.
Printer initialization fails.
Help initialization fails.
Error reporter fails.
The wrong level of DOS is used.
(continued)
The Code
Adapter
Level of
Support
this
Interface
Adapter
Code Level
Action
Refer to Action #1 after this
table.
Refer to Action #1 after this
table.
Refer to Action #1 after this
table.
Use optional parameter /l to
invoke the Ring diagnostic.
Use a different System Diskette.
A problem with the Ring
Diagnostic is present.
Use a different System Diskette.
A problem with the Ring
Diagnostic is present.
Remedy the problem with the
printer.
Use a different System Diskette.
A problem with the Ring
Diagnostic is present.
Use a different System Diskette.
A problem with the Ring
Diagnostic is present.
Make sure you use the DOS
version 4.0 or higher.
Ring
Diagnostic
Code Level

Advertisement

Table of Contents
loading

Table of Contents