1-316 Trouble locating and clearing procedures (continued)
Running a C7BERT
13
14
15
16
297-8021-544 Standard 14.02 May 2001
(continued)
Determine the traffic state of the link you want to test.
Note: The traffic state of the link appears under the Traf Stat header of the
MAP display.
If the traffic state
is ManB
is other than listed here
To manually busy the link, type
>BSY
link_no
and press Enter.
where
link_no
is the number of the link you want to test (0 to 15)
Example of a MAP response:
Traf Sync
LK Stat Stat Resource Stat Physical Access Stat
1
ManB Sync LIU7 109
Size of Posted Set = 1
If the BSY command
passed
failed
To deactivate the link, type
>DEACT
link_no
and press Enter.
where
link_no
is the number of the link you want to deactivate (0 to 15)
Note: The response can take 10 minutes. Wait for the status to change
InSv and confirm that the link is deactivated.
If the DEACT command
passed
failed
To access the C7BERT level of the MAP display, type
>C7BERT
and press Enter.
Do
step 15
step 14
InSv TTC7LKS1_TL
Do
step 15
step 66
FORCE
Do
step16
step 66
Link
Action
1 SZD