1-420 Trouble locating and clearing procedures (continued)
Testing an SPM OC3 interface module
Application
Use this procedure to test the DMS-Spectrum Peripheral Module (SPM)
NTLX71BA OC3 interface module using the MAP procedures.
Definition
Perform the specific steps located in the action section to test a faulty OC3
interface module.
Common procedures
None
Action
This procedure contains a summary flowchart and a list of specific steps. Use
the flowchart as an overview of the procedure. Follow the specific steps to
perform the procedure.
Summary of testing an SPM OC3 interface module
297-8021-544 Standard 14.02 May 2001
Post SPM
unit
Select OC3
Test OC3
Y
End
Passed
Contact next
N
level of support
?