1-446 Trouble locating and clearing procedures (continued)
TOPS MP Operator complaint (integrated)
Clearing voice communication path trouble
At the affected MP position
15
At the MAP
16
17
18
19
297-8021-544 Standard 14.02 May 2001
If test
fails
fails with base controller re-
placed
Replace base controller. Refer to the TOPS MP Card Replacement
Procedures and return to step 14.
To return to service, the busy CF3P from step 9, type
>POST G CF3P n
and press the Enter key.
where
n
is the busy CF3P from step 9
>RTS
and press the Enter key.
If the CF3P
returns to service
does not return to service
For additional help, contact the next level of support.
Perform the procedure Placing an MP position in service (integrated) .
The procedure is complete.
(end)
Do
step 15
step 17
Do
step 18
step 17