DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Trouble locating and clearing procedures (continued)
Removing a TOPS MPX terminal from service
and press the Enter key.
where
n
is number of position
To busy the selected position from the MAP, type:
>BSY
and press the Enter key.
Example of a MAP display:
BSY Passed
Are all the correct positions busy?
If position busy in step
is a redundant VPC (type 2)
is a type 1 or 3 position
is a VPC that is not redundant
(type 2) busy the TOPS MPX
positions that remain in the clus-
ter.
is last TOPS MPX position to
busy in a cluster
CAUTION
Both VPCs can go out of service.
DO NOT BUSY the TPC. This action takes both VPCs out of
service.
NOTE: You can only busy the TPC if the TPC is not
redundant.
To post the TPC that associates with the type 2 position at the TPC level, type:
>PM;POST TPC n
and press the Enter key.
where
TOPS MPX
Do
step 5 Examine the status dis-
play line to view the associated
TPC#. Note the TPC#.
step 9
step 2
step 5 Examine the status dis-
play line to view the associated
TPC#. Note the TPC#.
1-31
(continued)