DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Trouble locating and clearing procedures (continued)
To post the port for the replaced DDU, type
>PORT port_no
and press Enter.
where
port_no
is the port number of the DDU device
Example of a IOM MAP display:
Port 16
Unit
(SCSI)
User
Status
Record the unit number of the replaced DDU.
Note: In the example in step 3, the number of the DDU is 0.
Determine the state of the DDU.
Note: The state of the disk drive is under the Drive_State header on the
MAP display.
If the DDU is in
an allocated state
other than listed here
To determine if open files exist on the DDU, type
>ALLOC
and press Enter.
Example of a MAP display:
0
IMAGE
2800
1
XPMLOADS
2801
2
RTMLOADS
2802
.
.
.
7
SMDR
2807
8
AMA1
2808
9
TST
2809
10
AMA2
280A
If open files
are present
Replacing a 3.5 in. disk drive unit
NTFX32BA
0
system
Drive_State
Ready
On_line
Do
step 6
step 38
45000
D000
35000
D000
20000
D000
5000
D000
5000
D000
50
D000
500
D000
Do
step 37
1-85
(continued)