1-242 Trouble locating and clearing procedures (continued)
Replacing an NTFX39 bulkhead splitter unit
14
15
16
17
18
297-8021-544 Standard 14.02 May 2001
Example of a MAP response:
MPC
L
LCN
STATUS
–––
–––
––––––
0
3
1
INACTIVE none
0
3
2
INACTIVE none
If
one or more sessions is active
all sessions are inactive
Notify all users that there will be an interruption in the MPC service. Wait until
all sessions are inactive before you proceed. Repeat step 13 to verify MPC
session activity.
To manually busy the port and the port links, type
>BSY
FORCE
and press Enter.
Example of MAP response:
TYPE YES TO VERIFY FORCE, NO TO CANCEL COMMAND
Please confirm ("YES", "Y", "NO", or "N")
To confirm the command, type
>YES
and press Enter.
Example of MAP response:
REQUEST PASSED FOR PORTS
REQUEST PASSED FOR LINKS
If the BSY command
passed
failed
Repeat steps 11 to 16 for each MPC port on the IOM controller card.
The next action depends on any provisioned disk drive units (DDU) ports that
are on the controller card.
If provisioned DDU ports
are on the shelf
are not on the shelf
(continued)
CCC
SEC
PARDEV
–––
–––
––––––
none
none
none
none
Do
step 14
step 15
Do
step 17
step 57
Do
step 19
step 24
INP
OPEN
OWNER
–––
––––
–––––
FIL
0
none
FIL
0
none