DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Trouble locating and clearing procedures (continued)
Running a C7BERT for high-speed links
If you want to
perform an intermediate loop-
back C7BERT test
To activate a local loopback, type
>PMLOOP
LOCON
link_no
and press the Enter key.
where
link_no
is the number of the link you want to test (0 to 15)
If the response is
Link 1: Loopback Local
on completed
Link 1: Failed - PM-
LOOP
<Local|Re-
mote|Enable>
already active
Link
1:
Failed
C7BERT already active
on this link
Link 1: Failed - Link
state is invalid for
HSL PMLoop.
be SysB and DAct
anything else
At this point you have an option to test DS-1 carrier states or to continue with
this procedure. Testing DS-1 carrier states to make sure that they are in the
correct states is not necessary, but it can prevent a failure of the C7BERT.
If you do not want to test the DS-1 carrier states, go to step 39.
If you want to test the DS-1 carrier states, perform the "Test the DS-1 carrier
states" procedure in this document. After completing the procedure, go to
step 39.
To activate a remote loopback, type
>PMLOOP
RMTON
link_no
and press the Enter key.
where
link_no
is the number of the link you want to test (0 to 15)
Do
step 38
Do
step 24
step 27
is
step 32
-
step 16
Link must
step 78
1-351
(continued)