Nortel North American DMS-100 Instruction Manual page 598

Table of Contents

Advertisement

INSTRUCTIONS
You must compare the contents of the following screen with the
parameters you recorded while viewing the configuration of the token
ring adapter. If you did not configure the Token Ring Adapter, record
the address of the adapter on the TOPS MPX Configuration
Worksheet. Use the field labeled TOKEN RING ADAPTER ID. Also
record any other information known about this terminal in the
appropriate fields.
Press ENTER then the STA key to move to the second page of the
adapter information. Record the address of the Token Ring Adapter on
the TOPS MPX Configuration Worksheet.
Press ENTER
MESSAGE
Testing - Primary Token Ring Adapter
Please wait, this test takes up to 2 min.
INSTRUCTIONS
All tests passed.
You should now connect the Primary Token Ring Adapter cable
to the network.
ENTER = Continue
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Trouble locating and clearing procedures (continued)
TOPS MPX terminal system diagnostic
TOPS MPX
(continued)
Page 2 of 2
Page 1 of 1
Page 1 of 1
1-577

Advertisement

Table of Contents
loading

Table of Contents