Nortel North American DMS-100 Instruction Manual page 608

Table of Contents

Advertisement

TOPS MPX Token Ring LAN troubleshooting
The Ring Status Area
All ring status conditions appear in the list below. All ring status conditions,
except Normal, are highlighted on the screen and status conditions remain
highlighted until normal ring status returns. Generate a data area message
when ring status changes. Refer to Data Area Messages.
09/21/91 13:06:29 DFIPD001I Ring diagnostic started
––––––>
09/21/91
09/21/91
09/21/91
––––––>
F1 = Help
F6 = Ring test
Ring Status Conditions (Sheet 1 of 2)
Condition
Normal
Soft Error
Beaconing
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Trouble locating and clearing procedures (continued)
RING DIAGNOSTIC
10005A000133 000000A33832 000000A33832 000000A33832
13:06:50 DFIPD003I Printer enabled
13:06:56 DFIPD005I Ring test 1 started
13:06:56 DFIPD001E Ring error limit exceeded
10005A0002C2 000000000 7F 10005A000311F 00000000 6A
2 = Print
7 = Full E.R.
Soft Error
IDFIPD005I Ring test in progress - please wait
Ring Status
Description
The Ring Diagnostic processes information, and the ring
operates normally.
The ring experiences intermittent problems. Data
transmitted on the ring more than once are received
correctly.
The ring does not work. A broken wire or a defective
adapter can cause the ring to stop. When the problem is
isolated to one adapter, the system displays the logical
address of the problem to an operator. The system
displays the address of the problem in a data area
message.
3 = End
4 =
8 = Limited E.R. 9 = Reset Counts 10 = Pause
1-587
(continued)
5 =