Apz - Byte Set / Clear And Count; Bac - Branch Conditional On Count - Bosch Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS Functional Description

With integrated nc control
Table of Contents

Advertisement

ECODRIVE03-FL*-04VRS

APZ - Byte Set / Clear and Count

APZ 21022001

BAC - Branch Conditional on Count

BAC V600 +1234 V603
BAC 0345 +1234 12345
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Bit Field (see Parameter AA11)
Using this command, the status of up to 8 bits of the byte defined in
Parameter AA11 (Tool Wear) can be controlled. For each of up to 8 bits,
a separate counter is incremented by one whenever the bit status
changes from '0' to '1.' This enables the number of uses for a tool, and
therefore also its wear, to be determined.
Otherwise, this command operates like the APE command.
The program proceeds to the next instruction following the time period of
one cycle.
or
Preset Count
Actual Quantity Offset
Target Instruction
Like the COU command, this command allows the program to count
events, process cycles, quantities, etc.
First the quantity is incremented. Then, the actual quantity is compared
with the desired target quantity. If the programmed target quantity is not
reached, the program jumps to the target location. If the target quantity is
reached, the program proceeds to the next instruction.
Examples: a) Count following the event
0000
WAI
01.000
0001
PSI
1 +000050.000 250
0002
BAC
0000 +0000 00010
0003
JST
0000
Positioning is executed 10 times, and then the program waits for a new
start signal.
Examples: b) Count prior to the event
0000
BAC
0002 +0000 00010
0001
JST
0000
0002
PSI
1 +000050.000 250
0003
WAI
01.000
0004
JMP
0000
Positioning is executed 9 times, and then the program waits for a new
start signal.
For additional information on this command, see the explanation below
under the COU command.