6-30
Writing the User Program
CPJ - Compare and Jump
CPJ V600
= +
>
CPJ V600
= +12345.123 1234.12 0400
>
601
V602 V603
Target Instruction
Tolerance Range
Compare Operand 2
Operational Sign for Compare Operand 2
Compare Conditions
=
equal to
>
greater than
<
less than
>=
greater than or equal to
<=
less than or equal to
<>
not equal to
Compare Operand 1
The jump to the target location is executed when the comparison has
been made.
If the condition is not met, the program continues at the instruction with
the next higher number. For the compare conditons 'same' and 'different,'
the condition is met when the difference between the two operands lies
within the tolerance range.
Example: CPJ V600 >= +V601 0000.00 0400
V600 = 100.000
V601 = 090.000
The command branches to instruction 400
The program proceeds to the next instruction following the time period of
one cycle.
or
(with tolerance range)
(with tolerance range)
DOK-ECODR3-FL*-04VRS**-FK01-EN-P