Command Communications; 11.1 Parallel Interface; Diagnostic Led For Parallel Interface - Bosch Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS Functional Description

With integrated nc control
Table of Contents

Advertisement

ECODRIVE03-FL*-04VRS
11

Command Communications

11.1 Parallel Interface

Diagnostic LED for Parallel Interface

DOK-ECODR3-FL*-04VRS**-FK01-EN-P
DKC21.3
Three connectors serve as the parallel interface.
X1, X3 and X210
See also the Project Planning Manual and Section 13.
For diagnosing the parallel interface, four LEDs are available on the front
of the card. These LEDs signal the status of the control.
H211
H210
H213
green
off
- -
red
green
- -
red
orange
- -
red
red
- -
- -
- -
off
any
any
orange blinking
any
any
green blinking
Fig. 11-1: Diagnostic LED for Parallel Interface
The LEDs H212, H214 and H215 have no function
Note:
If all 6 LEDs turn orange approximately 10 seconds after start-
up, the parallel interface is not working. The firmware on the
programming module is either a wrong or defective version.
Command Communications
Definition
Status Diagnostic
Warnings
E-01xx
Error Message F-02xx
Error Message F-03xx
Command communications not
working
Initialization active
System is working
11-1