Immediate Cut / Cut Inhibit; Functions - Bosch Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS Functional Description

With integrated nc control
Table of Contents

Advertisement

8-34

Functions

Immediate Cut / Cut Inhibit

"Immediate Cut"
"Cut Inhibit"
Functions
LAL 1 000100.000
LAL 1
V600
The following functions can be activated in the LAL command:
Under the following conditions, synchronization can be immediately
initiated with a rising edge at the "Immediate Synchronization" input,
during processing of the LAL or LAR command:
During processing of the LAL/LAR command, as long as the starting
point has not yet been reached.
When cut inhibit is active.
With a rising edge at the "Inhibit Synchronization" input in Automatic
Mode, an inhibiting of the next synchronization is requested. This request
causes an inhibiting of the beginning of synchronization in the next LAL or
LAR command. In this case, the direction to proceed to the next
instruction does not occur in these commands. "Synchronization
Inhibit" can only be canceled using an "Immediate Synchronization"
(or by switching to Manual Mode).
Marker Flag M1.02.1 signals this status.
Default Length
00.00.0
or
I0.01.0
Inputs ee:
ee
= Immediate Cut (Immediate Synchronization)
ee+1
= Cut Inhibit (Inhibit Synchronization)
Product Length [IU]
Slave Axis: 1
Proceeding to the next instruction occurs as soon as the axis begins
synchronizing. Therefore, outputs (for example) can be set, even before
the synchronization is complete. The "rising edge" at Input "ee" is queried
until synchronization begins. Input "ee+1" is always queried when a
function is activated. A detected rising edge of Input "ee+1" is immediately
recognized and confirmed with Marker Flag M1.02.1.
ECODRIVE03-FL*-04VRS