ECODRIVE03-FL*-04VRS
LAR 1 000100.000 00.00.0 00.00.0
LAR 1
V600
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Part Length with Raster Pulse
or
I0.01.0 00.00.0
Raster Input "Start Synchronization":
Bit:
I4.00.3 / I4.00.4 = Fast Inputs (are currently evaluated
00.00.0 = Immediate Synchronization occurs
Inputs ee:
ee
ee+1
Offset Dimension [IU]
Slave Axis: 1
The raster input may only occur when the carriage is in its initial position.
The raster detection device must be placed in the direction of the material
from the initial position. The offset dimension is determined by the
distance between the initial position and the processing location to be
reached, when the raster is located precisely under the raster detection
device.
Proceeding to the next instruction occurs as soon as a rising edge is
recognized at the input "Start Synchronization" or "Immediate
Synchronization."
Synchronization Path
The acceleration path of the axis from standstill to synchronization is set
by the user in the CLG command.
Fig. 8-19: Acceleration Path
If the acceleration path is set as a smaller value, the acceleration set in
Parameter A108/109 can be exceeded. The acceleration can be
monitored using Parameter AA09.
M0 – M5
I0 - I4
Q0 - Q2
just like standard inputs!)
= Immediate Cut (Immediate Synchronization)
= Cut Inhibit (Inhibit Synchronization)
V
=
Material
s
2
*
Functions
2
a
8-35